Thermal Angel Blood and IV Fluid Infusion Warmer-Home
 
 
Home Products Comparison Video Demo Areas of Use Documentation Hypothermia Corporate
Contact Us Home
  Home Home
  Products Products
  Products Products
  Catalog Catalog
  Thermal Angel Fluid Warmer Thermal Angel Fluid Warmer
  Comparison to Other Fluid Warmers Comparison to Other Fluid Warmers
  Video Demonstration: Get Trained in 2 1/2 Minutes Video Demonstration: Get Trained in 2 1/2 Minutes
  Battery Battery
  Battery Bag Battery Bag
  Battery Charger Battery Charger
  Power Cable Power Cable
  9 Inch IV Extension 9 Inch IV Extension
  9 Inch IV Extension (Needle Free) 9 Inch IV Extension (Needle Free)
  Pricing and How To Buy Pricing and How To Buy
  Comparison Comparison
  Video Demo Video Demo
  Areas of Use Areas of Use
  Documentation Documentation
  Hypothermia Hypothermia
  Corporate Corporate
   
Information Newsletters
Print Tell a Friend

Thermal Angel Blood and IV Fluid Infusion Warmer Instructions


To see the Thermal Angel video (Click Here)

Package Contents:
The package contains one sterile and non-pyrogenic Thermal Angel TA-200 Blood and IV Fluid Infusion Warmer.  Federal law restricts this device for sale only by or on order of a physician.

Indication for Use:
For use when normothermic fluid is indicated.

Description:
The Thermal Angel is an in-line, battery-powered disposable, lightweight and completely portable blood and IV fluid infusion warming device, capable of intravenous application and irrigation warming.  The Thermal Angel can be used to help prevent fluid-induced hypothermia.  The Thermal Angel TA-200 will strive to achieve 38°C (100.4°F) ±3°C at a flow rate of 2 to 150 ml/min given a fluid input temperature of 20°C (68°F) with a fully charged TA-BCE Battery.

With changes in flow rate or input fluid temperature, the Thermal Angel TA-200 will require an adjustment period of approximately 15-30 seconds.  An internal sensor measures temperature at a rate of approximately 5000 times per second and adjusts power to the heaters accordingly.

Gather the Following:

  • Thermal Angel (TA-200)
  •  9 inch IV Extension Set (TA-9EXT) or similar
  • Battery (TA-BCE)
  • Battery Bag (TA-CC)
  • Power Cable (TA-CDC)
  • Battery Charger (TA-CAC)
  • IV Administration Set (end user provided)
  • Fluid (end user provided)

Thermal Angel and Accessories

    Preparation of Battery:
    The Thermal Angel TA-200 is powered by a fully charged reusable Battery (TA-BCE). The Battery is charged by the Battery Charger (TA-CAC) which requires 120 Volts AC.  When not in use, the Battery should remain connected to the Battery Charger to maintain the optimum charge level.

    Step 1:
    • Plug Battery into Battery Charger.
    • Plug Battery Charger into AC electrical outlet.
    • Allow Battery to charge for 14 hours if fully discharged.

    Thermal Angel Battery
    Step 2:
    • Verify charge status of Battery by pressing red button on Battery.
    • Green LED indicates a full charge.
    • Yellow LED indicates a moderate charge.
    • Red LED indicates an insufficient charge.
    Thermal Angel Battery
    Important:
    The LED indicators on the Battery are designed to display the charge condition when the Battery is not being used to power the Thermal Angel.  A false indication may be displayed during Battery charging or Thermal Angel operation.  Only check the charge status of the Battery when disconnected from the Battery Charger and Thermal Angel.

    Charging the Battery and powering the Thermal Angel are two separate operations. Do not charge the battery while the Thermal Angel is in operation.

    The Battery should be fully charged prior to first use.  The Battery should be recharged after each use.  The Battery does not have a memory effect and may be recharged even though it has not been fully discharged.

    The Battery has a life expectancy of about 150 charge cycles.

    With a fluid input temperature of 20°C (68°F), a fully charged TA-BCE Battery will last through approximately 2 to 4 liters of IV fluid at various flow rates.  With a fluid input temperature of 10°C (50.0°F), a fully charged TA-BCE Battery will last through approximately 1 to 3 units of blood at various flow rates.

    Preparation of the Thermal Angel TA-200:
    • Visually Inspect the Thermal Angel and 9 Inch IV Extension Set to insure there is no damage to the packaging or unit.
    • Use aseptic technique to open the Thermal Angel and 9 Inch IV Extension Set.
    Thermal Angel in Sterile Bag
    Step 1:
    • Remove the female luer cap from the inlet end of the Thermal Angel.
    Thermal Angel End Cap
    • Connect IV tubing to the female luer.  Tighten until resistance is met.  Do not over tighten!
    Thermal Angel and luer
    Step 2:
    • Remove the male luer cap from the outlet end of the Thermal Angel.
    Removing the male luer
    • Connect 9 Inch IV Extension Set to the male luer.  Tighten until resistance is met.  Do not over tighten!
    Add extension set
    Step 3:
    • Connect assembled IV line to fluid source and prime the line.
    Connect IV line
    Step 4:
    • Connect the male end of the Power Cable to the inlet end cap of the Thermal Angel.
    Connect Power Cable
    • Connect the female end of the Power Cable to the Battery.
    Connect Power Cable to Battery
    • The green LED on the Thermal Angel inlet end cap should display continuous illumination without blinking.
    Confirm a green LED
    Step 5:
    • Connect 9 Inch IV Extension Set to IV catheter.
    • Engage roller clamp on IV tubing to adjust flow.
    Adjust the flow

    Blood Infusion:
    Always use with approved blood administration set. When infusing blood through the Thermal Angel TA-200, follow the instructions provided with the blood administration set.  The Thermal Angel TA-200 is intended to function as an extension of the IV tubing.  Replace the Thermal Angel TA-200 when replacing the blood administration set.  Refer to your facility/organization protocol.

    Adverse events should be handled by discontinuing the use of the Thermal Angel TA-200 and immediately notifying the manufacturer or manufacturer's representative.

    In circumstances where instructions are unclear about changing the blood administration set, replace the Thermal Angel TA-200 after infusion of two units of blood.
     
    Specifications and Characteristics:
    The Thermal Angel TA-200 is a single use item.  When necessary, cleaning should consist of wiping the external covering of the unit with a damp cloth.  Do not submerge, sterilize or autoclave the Thermal Angel TA-200.

    The Thermal Angel TA-200 will strive to achieve 38°C (100.4°F) ±3°C at a flow rate of 2 to 150 ml/min given a fluid input temperature of 20°C (68°F) with a fully charged TA-BCE Battery.  This temperature is set by the manufacturer and may not be altered.

    With changes in flow rate or input fluid temperature, the Thermal Angel TA-200 will require an adjustment period of approximately 15-30 seconds.  The Thermal Angel TA-200 is designed to operate with flow rates of 2 to 150 ml/min.  Operation beyond the design specifications will result in lower output temperature.

    Thermal Angel TA-200 is compatible with any existing IV administration set that utilizes standard luer connections.

    Incoming fluid temperature must be between 4°C (39.2°F) and 38°C (100.4°F).

    The Thermal Angel TA-200 requires a fully charged TA-BCE Battery.
     
    Thermal Angel TA-200 Device Life Expectancy:
    The Thermal Angel TA-200 may be left in-line until the IV site or line is changed, up to 72 hours. The Thermal Angel TA-200 will perform for approximately 72 hours of accumulated use while receiving power from multiple fully charged Batteries. After approximately 72 accumulated hours of use, the Thermal Angel TA-200 will continue to operate until power is removed; however, it will not power up again and should be discarded.  Dispose of the Thermal Angel TA-200 using biohazard precautions. 

    If the incoming fluid temperature exceeds 47°C (116.6°F) and the power is connected, the failsafe circuit will be activated. Activation of the failsafe circuit will result in permanent operational termination.

    The Battery, Battery Bag, Battery Charger and Power Cable are reusable.
     
    Caution!:
    Entry into the product housing is not authorized and should not be attempted. Any attempt to gain entry into the internal components of the Thermal Angel will void any warranty claims.  Unlawful entry into the product housing can lead to product malfunction.

    Use of the Thermal Angel TA-200 inconsistent with its instructions may result in failure of the device.

    Discontinue use if the green LED is off or blinking.

    Store the Thermal Angel TA-200 at temperatures between 0°C (32°F) and 40°C (104°F).  Exceeding these limits may cause the device to malfunction.

    Testing has not yet determined maximum shelf life.

    The Thermal Angel TA-200 has not been evaluated within the confines of a MRI.

    Troubleshooting:

    Problem

    Cause

    Solution

    No power or green LED not illuminated on inlet end cap

    Power Cable not secure to Battery and/or Thermal AngelSecure connections
    Inadequate Battery chargeCharge Battery
    Thermal Angel, Battery or Power Cable malfunctionReplace
    Blinking green LED on inlet end of capThermal Angel malfunctionDisconnect Power Cable and reconnect. If LED continues to blink, replace Thermal Angel.
    Fluid input temperature too low or too highVerify fluid input temperature is between 4°C (39.2°F) and 38°C (100.4°F)
    No flowRoller clamp or stopcock closedOpen as desired
    Kink in IV lineStraighten or replace IV line

    Warranty Information:
    The Thermal Angel TA-200 is warranted to be free from manufacturer defect and is covered for one year from the date of purchase.

    Patent:
    This product was manufactured for Estill Medical Technologies, Inc. Under Patent Nos. 6,142,974 & 6,139,528 (and other patents pending).

    To see the Thermal Angel video (Click Here)
     

    Downloadable Documents:

    Thermal Angel TA-200 Instructions
     Thermal Angel TA-200 Quick Steps

     

    I work in a bush hospital in rural Alaska. Located just below the Arctic Circle, we receive and treat many hypothermic patients in the ER. In early spring of last year, a man was lost and spent the night on the ice in severe winds and cold...
    Louis A. Murphy
    RN BSN
    read testimonial
    I'm a believer in the Thermal Angel.  Best piece of medical equipment I had with me in (***).
    Scott S.
    U.S. Military
    read testimonial
       
    Information Newsletters
     
     
     
     
     
    Thermal Angel Blood and IV Fluid Infusion Warmer
    Estill Medical Technologies, Inc., 4144 N Central Expressway, Suite 260, Dallas, Texas 75204.
    U.S. Toll Free: (877) 354-0286 | Phone: (214) 561-6001 | Fax: (214) 561-1930 | www.thermalangel.com
    Copyright © 2008 Estill Medical Technologies, Inc..
      Quick links:
    Video Demo: 2 1/2 Minutes
    Comparison to Other Warmers
    Product Catalog
    Contact Us